Nikon Eclipse LV100ND

SKU:Ni-Eclipse-LV100ND

A manual microscope with episcopic/diascopic illumination, which meets the various needs of observation, inspection, research, and analysis across a wide range of industrial fields. Higher NA and a longer working distance than ever before mean superior optical performance and efficient digital imaging. Max. sample size: 150 x 150 mm.

Key benefits:

  • Modularized microscope body applicable with various observations and tasks
  • Newly developed CFI60-2 series provides the ultimate in long working distance levels and the most advanced chromatic aberration in a light weight body
  • Easy digital imaging

Product Information (PDF Format)

Nikon Industrial Instruments Catalog (PDF Format)

Need A Quote?

Need assistance with your order? We can help.

Get Quote

Microscope Type

  • Combined reflected/transmitted illumination models
  • Manual type

Modularized microscope body applicable with various observations and tasks
Compatible with brightfield, darkfield, simple polarizing, DIC, epifluorescence and two-beam, interferometry observations. Furthermore, phase contrast and DIC observation with diascopic illumination are also possible.
It supports diverse and advanced research, analysis and inspection.

Compatible observation methods:

LV100ND/ LV100DA-U compatible methods

Compatible stages
LV-S32 3×2 stage (Stroke: 75 x 50 mm with glass plate)
*Can be fitted with LV-S32SGH slide glass holder
LV-S64 6×4 stage (Stroke: 150 x 100 mm with glass plate)
LV-SRP P revolving stage
P-GS2 G stage 2 (Used with stage adapter LV-SAD)
NIU-CSRR2 Ni-U right handle rotatable ceramic stage (Stroke: 78 x 54 mm)
C-SR2S right handle stage (Stroke: 78 x 54 mm: Used with stage adapter LV-SAD)

Newly developed CFI60-2 series
Newly developed CFI60-2 series provides the ultimate in long working distance levels and the most advanced chromatic aberration in a light weight body
CFI60-2 series offers higher NA and longer working distances than ever before.

Easy digital imaging
Through the combination of the Intelligent Nosepiece LV-NU5I and Nosepiece Adapter LV-INAD, information about the objective in use is detected and displayed in the monitor via the camera control unit. In addition, the information is automatically converted to appropriate calibration data when changing magnification.

Digital Camera System for Microscopy Digital Sight Series
Imaging Software NIS-Elements

Base unit:

Maximum sample height: 38 mm (when used with LVNU5AI U5AI nosepiece and LV-S32 3×2 stage / LV-S64 6×4 stage) 12V50W internal power source for dimmer, coarse and fine adjustment knobs Left: coarse and fine adjustment / Right: fine adjustment, 40 mm stroke Coarse adjustment: 14 mm/turn (with torque adjustment, refocusing mechanism) Fine adjustment: 0.1 mm/turn (1 μm/graduation)

Nosepieces:

C-N6 ESD Sextuple Nosepiece ESD
LV-NU5 Universal Quintuple Nosepiece ESD
LV-NBD5 BD Quintuple Nosepiece ESD
LV-NU5I Intelligent Universal Quintuple Nosepiece ESD
D-ND6 Sextuple DIC Nosepiece

Episcopic Illuminator:
LV-UEPI-N
LV-LH50PC 12V50W Precentered Lamphouse Bright/darkfield switch and linked aperture stop (centerable), field diaphragm (centerable), accepts ø 25 mm filter (NCB11, ND16, ND4), polarizer/analyzer; equipped with noise terminator

LV-UEPI2
LV-LH50PC 12V50W Precentered Lamphouse HG precentered fiber illuminator: C-HGFIE (with light adjustment) *option Bright/darkfield switch and linked aperture stop (centerable), field diaphragm (centerable), automated optical element switching feature matched to brightfield, darkfield, and epi-fluorescence switch Accepts ø 25 mm filter (NCB11, ND16, ND4), polarizer/analyzer, λ plate, excitation light balancer; equipped with noise terminator

Diascopic Illuminator:

LV-LH50PC 12V50W Precentered Lamphouse (Fly Eye optical system)
Internal aperture, field diaphragm, filter (ND8, NCB11); transmitted/reflected selector switch; 12V100W also available (option)

Eyepiece tubes:

LV-TI3 trinocular eyepiece tube ESD (Erected image, FOV: 22/25)
LV-TT2 TT2 tilting trinocular eyepiece tube (Erected image, FOV: 22/25)
P-TB Binocular Tube (Inverted image, FOV: 22)
P-TT2 Trinocular Tube (Inverted image, FOV: 22)

Stages:

LV-S32 3×2 stage (Stroke: 75 x 50 mm with glass plate) / LV-S32SGH slide glass holder
LV-S64 6×4 stage (Stroke: 150 x 100 mm with glass plate), LV-SRP P revolving stage / P-GS2 revolving stage: Used with stage adapter LV-SAD NIU-CSRR2 Ni-U right handle rotatable ceramic stage (Stroke: 78 x 54 mm), C-SR2S right handle stage (Stroke: 78 x 54 mm: Used with stage adapter LV-SAD)

Condensers:

LWD achromat condenser (brightfield)
LV-CUD U condenser dry (phase contrast, diascopic DIC, darkfield)
Achromat 2x-100x slide condenser (brightfield)
DF dry condenser (darkfield), and others

Eyepieces:

CFI eyepiece series

Objective lenses:

Industrial Microscope CFI60-2/CFI60 optical system Objective lens series: Combinations in accordance with the observation method

ESD performance:

1,000 to 10V, within 0.2 sec. (excluding certain accessories)

Power consumption:

1,2A/75W

Weight:

Approximately 9.6kg

Speak to a Scientist

McCrone Group's analytical scientists are available to answer your questions. Have a project you'd like to discuss? Give us a call or email us!