Nikon Eclipse LV100NDA LED
SKU:NI-LV100NDA-LED
The ECLIPSE LV100NDA LED is a flexible, modular upright microscope designed for episcopic and diascopic optical contrast techniques to meet the needs of observation, inspection, research, and analysis across a wide range of industrial fields..
The newly developed high color-rendering LED light source upgrades brightness, color, and color-rendering properties compared to the existing halogen source, extending lamp life from 1,100 to 50,000 hours. Space efficiency is improved by incorporating the LED light source into the microscope stand (LV100NDA LED and LV100ND LED), reducing footprints by up to approximately 100 mm, depending on the model.
Key benefits:
- Modular microscope body applicable with various observations and tasks
- Enhanced usability: The system offers high scalability through the compatibility of accessories between old and new products while providing extensive expandability with a wide range of accessories.
- CFI60-2 series provides the ultimate in long working distance levels and the most advanced chromatic aberration in a light weight body
- Easy digital imaging
Microscope Type
- Combined reflected/transmitted illumination models
- Motorized type (Nosepiece / light intensity / aperture stop / observation method selector)
Modularized microscope body applicable with various observations and tasks
Compatible with brightfield, darkfield, simple polarizing, DIC, epifluorescence and two-beam, interferometry observations. Furthermore, phase contrast and DIC observation with diascopic illumination are also possible.
It supports diverse and advanced research, analysis and inspection.
Compatible stages
LV-S32 3×2 stage (Stroke: 75 x 50 mm with glass plate) / LV-S32SGH slide glass holder
LV-S64 6×4 stage (Stroke: 150 x 100 mm with glass plate)
LV-SRP P revolving stage
NIU-CSRR2 Ni-U right handle rotatable ceramic stage (Stroke: 78 x 54 mm)
C-CSR2S right handle stage (Stroke: 78 x 54 mm: Used with stage adapter LV-SAD)
CFI60-2 series optical system
CFI60-2 series provides the ultimate in long working distance levels, higher NA, and the most advanced chromatic aberration in a light weight body
Easy Digital Imaging
Nikon Digital Sight cameras efficiently capture images of a sample and deliver them to the image processing software of the NIS-Elements suite, together with microscope data on the objective lens used, magnification setting and light intensity. In addition, the information is automatically converted to appropriate calibration data when changing magnification.
Digital Camera System for Microscopy Digital Sight Series
Imaging Software NIS-Elements
Base unit:
Maximum sample height: 33 mm (when used with LVNU5AI U5AI nosepiece and LV-S32 3×2 stage / LV-S64 6×4 stage)
12V50W internal power source for dimmer, coarse and fine adjustment knobs Left: coarse and fine adjustment / Right: fine adjustment, 40 mm stroke Coarse adjustment: 14 mm/turn (with torque adjustment, refocusing mechanism) Fine adjustment: 0.1 mm/turn (1 µm/graduation)
Nosepieces:
LV-NU5AI Motorized Universal Quintuple Nosepiece
(High-durability motorized 5-hole universal nosepiece)
Episcopic Illuminators:
LV-UEPI2A
High color-rendering LED Lamphouse C-LL-I: 50,000 hours of life *1
Fluorescence LED light source D-LEDI (with light adjustment (PC controllable)) *option
Motorized operation and control of illumination selector turret Motorized aperture stop linked to bright/darkfield selector (automatic optimization matched to objective lens), field diaphragm (centerable)
Accepts ø 25 mm filter (LV-C-LCB), polarizer/analyzer, λ plate, excitation light balancer; equipped with noise terminator
Diascopic Illuminator:
Built-in high color-rendering LED Lamphouse C-LL-I (50,000 hours of life; estimated based on Nikon regulations)
(Fly Eye optical system)
Internal aperture, field diaphragm, filter (45C-LCB); transmitted/reflected selector switch
Eyepiece tubes:
LV-TI3 trinocular eyepiece tube ESD (Erected image, FOV: 22/25)
LV-TT2 TT2 tilting trinocular eyepiece tube (Erected image, FOV: 22/25)
P-TB Binocular Tube (Inverted image, FOV: 22)
P-TT2 Trinocular Tube (Inverted image, FOV: 22)
Stages:
LV-S32 3×2 stage (Stroke: 75 x 50 mm with glass plate) / LV-S32SGH slide glass holder
LV-S64 6×4 stage (Stroke: 150 x 100 mm with glass plate)
LV-SRP P revolving stage
NIU-CSRR2 Ni-U right handle rotatable ceramic stage (Stroke: 78 x 54 mm)
C-CSR2S right handle stage (Stroke: 78 x 54 mm: Used with stage adapter LV-SAD)
Condensers:
LWD achromat condenser (brightfield)
LV-CUD U condenser dry (phase contrast, diascopic DIC, darkfield)
Achromat 2x-100x slide condenser (brightfield)
DF dry condenser (darkfield), and others
Eyepieces:
CFI eyepiece series
Objective lenses:
Industrial Microscope CFI60-2/CFI60 optical system Objective lens series: Combinations in accordance with the observation method
ESD performance:
1,000 to 10V, within 0.2 sec. (excluding certain accessories)
Power consumption:
0.7 A / 58 W (reference value based on Nikon regulations)
Weight:
Approximately 10kg
Speak to a Scientist